Pump Selection Guide
A helpful tool to choose the appropriate pump according to its resistance to different chemicals, control features, outputs and pressures.
STEP #1
a) Scroll to Diaphragm, Peristaltic, or Piston pump table to meet your application requirements. b) From this table note a PRELIMINARY MODEL SERIES selection based on Max Output, Max Pressure, and Control needs. These are SERIES MAXIMUMS; smaller outputs and pressures can be selected in STEP #3.
STEP #2
Once the appropriate PRELIMINARY MODEL SERIES has been determined above, select the appropriate liquid end code from the lower tables for the chosen make (Walchem, Stenner, A&F). Note: check the Chemical Resistance Chart for liquid end material acceptability.
STEP #3
a) You should now have the appropriate PRELIMINARY MODEL SERIES with LIQUID END CODE for your application.
b) To complete the FULL MODEL CODE, click on the PRELIMINARY MODEL link you have chosen. This link will direct you to the pump web page, select your options to finalize your FULL MODEL CODE with the defined maximum output and pressure. Note: there are pump brochures, manuals, dimensions and specifications downloads.
DIAPHRAM PUMPS |
MAX SERIES OUTPUT |
MAX SERIES PRESURE |
CONTROL |
CHEMICAL RESISTANCE |
|
MAKE |
PRELIMINARY MODEL SERIES SELECTION |
GPH |
ml/min |
PSI |
MANUAL ON/OFF |
DIGITAL INPUT/OUTPUT |
ANALOG INPUT |
STOP/PRESTOP INPUT |
LIQUID END |
DRIVE |
Walchem |
EWN-B******R |
3.2 |
200 |
290 |
YES |
YES |
YES |
YES |
See chart below |
SOLENOID |
Walchem |
EWN-C******R |
6.7 |
420 |
250 |
YES |
YES |
YES |
YES |
See chart below |
SOLENOID |
Walchem |
EWN-B******Y |
3.2 |
200 |
290 |
YES |
MORE |
YES |
YES |
See chart below |
SOLENOID |
Walchem |
EWN-C******Y |
6.7 |
420 |
250 |
YES |
MORE |
YES |
YES |
See chart below |
SOLENOID |
|
|
|
|
|
|
|
|
|
|
|
Walchem |
EZB**D*-** |
3.2 |
200 |
150 |
YES |
NO |
NO |
NO |
See chart below |
SOLENOID |
Walchem |
EZC**D*-** |
6.3 |
400 |
150 |
YES |
NO |
NO |
NO |
See chart below |
SOLENOID |
|
|
|
|
|
|
|
|
|
|
|
Walchem |
EHE**E*-** |
20 |
1250 |
150 |
YES |
YES |
YES |
YES |
See chart below |
SOLENOID |
|
|
|
|
|
|
|
|
|
|
|
Walchem |
EWN-C31P**RV-HV* |
2.3 |
150 |
73 |
YES |
YES |
YES |
YES |
See chart below |
SOLENOID |
Walchem |
EHE36E*-HV |
4.0 |
252 |
73 |
YES |
YES |
YES |
YES |
See chart below |
SOLENOID |
Walchem |
EHE46E*-HV |
8.0 |
505 |
60 |
YES |
YES |
YES |
YES |
See chart below |
SOLENOID |
|
|
|
|
|
|
|
|
|
|
|
A&F |
V-6 |
2.0 |
126 |
100 |
YES |
NO |
NO |
NO |
See chart below |
MOTOR |
|
|
|
|
|
|
|
|
|
|
|
Walchem |
LKN**A-** |
114.3 |
7212 |
225 |
YES |
NO |
NO |
NO |
See chart below |
MOTOR |
Walchem |
LKN**B-** |
114.3 |
7212 |
225 |
YES |
NO |
NO |
NO |
See chart below |
MOTOR |
Walchem |
LKN**C-** |
114.3 |
7212 |
225 |
YES |
NO |
NO |
NO |
See chart below |
MOTOR |
Walchem |
LKN**D-** |
114.3 |
7212 |
225 |
YES |
NO |
YES |
NO |
See chart below |
MOTOR |
Walchem |
LKN**E-** |
114.3 |
7212 |
225 |
YES |
NO |
YES |
NO |
See chart below |
MOTOR |
Walchem |
LKN**F-** |
114.3 |
7212 |
225 |
YES |
NO |
NO |
NO |
See chart below |
MOTOR |
Walchem |
LKN**G-** |
114.3 |
7212 |
225 |
YES |
NO |
NO |
NO |
See chart below |
MOTOR |
Walchem |
LKN**N-** |
114.3 |
7212 |
225 |
YES |
NO |
NO |
NO |
See chart below |
N/A |
PERISTALTIC PUMPS |
MAX SERIES OUTPUT |
MAX SERIES PRESURE |
CONTROL |
CHEMICAL RESISTANCE |
|
MAKE |
PRELIMINARY MODEL SERIES SELECTION |
GPH |
ml/min |
GPD |
PSI |
TYPE |
MANUAL ON/OFF |
LIQUID END |
DRIVE |
Stenner |
45MF * * * * * |
2.08 |
131.25 |
50 |
100 |
FIXED |
YES |
See chart below |
MOTOR |
Stenner |
45MJ * * * * * |
2.08 |
131.25 |
50 |
100 |
ADJUSTABLE |
YES |
See chart below |
MOTOR |
Stenner |
85MF * * * * * |
3.54 |
223.37 |
85 |
100 |
FIXED |
YES |
See chart below |
MOTOR |
Stenner |
85MJ * * * * * |
3.54 |
223.37 |
85 |
100 |
ADJUSTABLE |
YES |
See chart below |
MOTOR |
Stenner |
100F * * * * * |
4.17 |
263.13 |
100 |
100 |
FIXED |
YES |
See chart below |
MOTOR |
Stenner |
100J * * * * * |
4.17 |
263.13 |
100 |
100 |
ADJUSTABLE |
YES |
See chart below |
MOTOR |
Stenner |
170F * * * * * |
7.08 |
446.75 |
170 |
100 |
FIXED |
YES |
See chart below |
MOTOR |
Stenner |
170J * * * * * |
7.08 |
446.75 |
170 |
100 |
ADJUSTABLE |
YES |
See chart below |
MOTOR |
Stenner |
SVP1 * * * * * |
3.54 |
223.37 |
85 |
100 |
VARIABLE |
YES |
See chart below |
MOTOR |
Stenner |
SVP4 * * * * * |
3.54 |
223.37 |
85 |
100 |
VARIABLE |
YES |
See chart below |
MOTOR |
PISTON PUMPS |
MAX SERIES OUTPUT |
MAX SERIES PRESURE |
CONTROL |
CHEMICAL RESISTANCE |
|
MAKE |
PRELIMINARY MODEL SERIES SELECTION |
GPH |
ml/min |
GPD |
PSI |
ANALOG |
MANUAL |
LIQUID END |
DRIVE |
A&F |
V-7 |
2.0 |
120 |
48 |
100 |
NO |
YES |
See chart below |
MOTOR |
A&F |
V-10-1 |
60 |
3600 |
1440 |
1000 |
YES |
YES |
See chart below |
MOTOR |
A&F |
V-10-2 |
120 |
7200 |
2880 |
1000 |
YES |
YES |
See chart below |
MOTOR |
A&F |
V-10-3 |
42 |
2700 |
1008 |
1000 |
YES |
YES |
See chart below |
MOTOR |
A&F |
V-10-4 |
56 |
3600 |
1344 |
1000 |
YES |
YES |
See chart below |
MOTOR |
USE THE FOLLOWING THREE MAKE CHARTS (Walchem, Stenner, A&F) TO DETERMINE THE SUITABLE LIQUID END CODE GIVEN MATERIALS ON CHEMICAL RESISTANCE CHART.
WALCHEM: LIQUID END CODE (see Chemical Resistance Chart for Materials)
WALCHEM |
|
|
|
|
|
|
Connections |
Liquid End Code |
Pump Head & Fittings |
Diaphragm |
Valve Balls |
Valve Seat |
Valve Seals |
Gasket |
E-Class |
LK |
PC(H) |
GFRPP |
PTFE BONDED TO EPDM |
CE |
FKM |
FKM |
PTFE |
PE Tubing |
n/a |
PE(H) |
GFRPP |
CE |
EPDM |
EPDM |
n/a |
VC |
PVC |
CE |
FKM |
FKM |
NPTM |
VE |
PVC |
CE |
EPDM |
EPDM |
n/a |
VF |
PVC |
PTFE |
EPDM |
EPDM |
n/a |
VM |
M PVC |
CE |
FKM |
FKM |
n/a |
FC |
PVDF |
CE |
PCTFE |
PTFE |
n/a |
TC |
PVDF |
CE |
FKM |
FKM |
NPTM |
HV |
PVC |
CE |
PCTFE |
FKM |
NPTM |
n/a |
SH |
SS |
HC |
SS |
PTFE |
1/4" NPTF |
n/a |
VS |
PVC |
HC/SS |
304SS |
EPDM |
n/a |
NPTM |
VH |
PVC |
HC |
PVC |
EPDM |
n/a |
NPTM |
S6 |
316SS |
HC |
316SS |
|
n/a |
NPTM |
STENNER: LIQUID END CODE (see Chemical Resistance Chart for Materials)
STENNER |
|
|
Liquid End Code |
Pump Tube |
Connector |
Suction/Discharge Tubing |
S |
Santoprene |
PVC |
PE |
T |
Tygothane/Versilon |
PVC |
PE |
A&F: LIQUID END CODE (see Chemical Resistance Chart for Materials)
A&F |
|
|
|
Liquid End Code |
Head / Check Valve/ Piston |
Packing Set |
Diaphragm*** |
Blank |
Carbon Steel |
Buna N* |
PTFE** |
SS |
303SS |
PTFE* |
PTFE** |
S6 |
316SS |
PTFE* |
PTFE** |
C20 |
Alloy 20 |
PTFE* |
PTFE** |
HC |
Alloy 276 |
PTFE* |
PTFE** |
* Viton / PTFE / Buna N may be specified at the time of order. |
** Viton or Neoprene may be specified at time of order. |
*** Applies to V-6 pumps only. |
|